Kehua UPS Power Supply YTR11 Series
YTR series single-phase input, single-phase output UPS
Digital control · Three-level technology · High-frequency power conversion
I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
The YTR series single-phase input and single-phase output UPS utilizes digital control technology, three-level technology, and high-frequency power conversion technology, featuring compact size, high performance, and high reliability, with significant energy-saving benefits that greatly reduce operating costs. It integrates multiple functions such as AC voltage stabilization, backup power supply, and spike and surge absorption, meeting power protection requirements in harsh grid environments and providing clean, safe, and stable power to loads.
I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Product Specifications
- · Rated capacity:1/2/3/6/10kVA
- · Input/output voltage208/220/230/240Vac
- · Rated frequency:50/60Hz (adaptive)
- · Installation methodVertical type
- · Topological structure: Dual Conversion Online Type
- · Power supply systemSingle-in, single-out.
Product Highlights
I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Digital control, leading technology.
- Advanced digital control technology enables precise and rapid data processing, with fast fault diagnosis and handling capabilities, comprehensive protection functions, and higher reliability.
- - Increase circuit integration, optimize circuit design, enhance anti-interference capability, and achieve more stable performance.
Dynamic speed regulation, efficient cooling
- · Intelligent dynamic speed adjustment extends the service life of the fan, further improves overall machine efficiency, and reduces losses.
- · Reduce the overall machine noise to create a green and comfortable working environment for customers.
Green Power, Bidirectional Protection
- Input power factor >0.99, improving electrical energy utilization, effectively avoiding additional energy losses, eliminating grid pollution, and reducing energy consumption costs.
- All components comply with the international environmental RoHS standard, being green and harmless.
Take things as they come; highly adaptable.
- Ultra-wide voltage input range, adaptable to voltage ranges in various usage environments, easily handling harsh power conditions.
- Adapt to generator as AC source input, effectively isolate poor-quality power generated by the generator, avoid grid pollution, and provide pure, safe, and stable power to the load.
Flexible Configuration · Smart Communication
I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Standard machine / Long machine - choose as needed
- · Standard model - Can provide power protection for electrical equipment with short time delays.
- · Extended-delay model - The number of battery cells can be configured arbitrarily according to user needs, extending backup time and ensuring uninterrupted power supply for equipment.
IT equipment room
Precision instruments
Smart device
Rich interfaces, multiple communication methods.
- Multi-dimensional communication methods to meet users' diverse communication preferences.
- Standard: RS232, EPO; Optional: SNMP, USB, RS485+ dry contacts, protocol converter card, etc.
- Multiple communication methods enable intelligent monitoring between computers and UPS, meeting customers' remote management needs. Comprehensive communication management functions keep you fully informed of device status.
USB card
RS485 + dry contact card
Protocol conversion card
Battery management, proprietary patent.
- Smart battery detection and battery self-test, predicting battery health status in advance.
- Real-time battery remaining capacity display for easy monitoring of battery working status.
- - Complete battery protection functions to extend battery service life.
Outstanding performance, excellent metrics.
- Overall efficiency up to 95%This greatly saves energy consumption and significantly reduces customers' operating costs.
- · Super strong overload capacity, with load 130% Stable and sustainable 10 minutes Uninterrupted power supply ensures the safe and normal operation of equipment.
IT server room
Precision instruments
Smart device
* Suitable for 6-10kVA models
| Specification Model | YTR1101 | YTR1101L | YTR1102 | YTR1102L | YTR1103 | YTR1103L | YTR1106 | YTR1106L | YTR1110 | |
| I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
输入 Features |
Input formatI'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Input (voltage a) range |
Single-phase three-wire | ||||||||
| V c | 110 to 300I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
40-70 |
80-275 | ||||||||
| Input frequency range (Hz) | 50/60Hz auto-adaptive | |||||||||
| Input power factor | >0.99 (full load) | |||||||||
| Input current harmonics | <5% (full load) Default 1 (92 (161 knots 9~22~204 knots 0* adjustable 12-sided V panel can be set panel), default 16 knots) | |||||||||
| Battery voltage (Vdc)I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Output V rated power |
24 | 36 | 48 | 72 | 72 | 96 | ||||
| I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Output Features |
(A/W) | 1000/900 | 2000/1800 | 3000/2700 | 6000/5400 | 10000/9000 | ||||
| Output power factor | 0.9 (can be set to 1.0 at 0~30°C; 1-3kVA requires software setting) | |||||||||
| Output voltage (Vac) | Default 220, 208/220/230/240±1% | |||||||||
| Output frequency (Hz)I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Waveform distortion |
Synchronous mode: 50/60±10%; Self-oscillation mode: 50/60±0.2% | |||||||||
| Bypass inverse T to Dv conversion) timeI'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
( |
<2% (linear load), <3% (non-linear load) | <1% (linear load), <3% (non-linear load) | ||||||||
| milliseconds (ms) | 0 | |||||||||
| System efficiency | 100%-130% overload: maintain for 1 minute; 131%-210%: up to 5 minutes; load <115%: long-term; 115%-130% overload: 10 minutes.I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Overload maintained for 1s; |
|||||||||
| Inverter overload capacity | More than 150%: | 131% 150% overload: 30s Overload above 150%: 0 5s | ||||||||
| Output method | Output socket | Output socket + terminal block | Terminal block | |||||||
| I'll translate the Chinese text to English. However, you haven't provided any Chinese text to translate. Please provide the Chinese text you'd like me to translate.
Other special 性 |
DC start-up | Possess | ||||||||
| Communication function | RS232, EPO (standard); USB, SNMP, RS485 + dry contacts, protocol converter card, etc. | |||||||||
| Panel display | LED | Blue screen LCD | ||||||||
| Noise (dB) | <45 | Less than 50 | 55 | |||||||
| Alarm function | Low battery voltage, abnormal mains power, output overload. | |||||||||
| Protection function | Battery undervoltage protection, overload protection, short circuit protection, over-temperature protection, input overvoltage protection, UPS fault. | |||||||||
| Operating temperature (℃) | -5~40 | |||||||||
| Environmental humidity dimensions | 0~95%, non-condensing | |||||||||
| (Width × (m depth m ×) height) | 145×360×225 | 190×400×330 | 230×502×553 | 190×422×337 | ||||||
| Weight (kg) | 8.8 | 4.9 | 17 | 8.5 | 22.2 | 9.3 | 54.5 | 11.0 | 12.5 | |
